KOROK® INTERTENANCY 

FOR APARTMENTS

Conventional framed wall systems rely on the internal linings for fire-resistance. Penetrating these linings potentially destroys the fire-rated barrier. In the KOROK® Intertenancy System the main fire barrier located between frames is designed to protect the structure on the side opposite the fire.

 

 

 

 

 

KOROK® Systems Summary Table - for Apartments

SPEC. CODESTCFRRWALL THICKNESS*FRAMECAVITYSYSTEM SUMMARY
KIM01 57 -/60/60 194mm 64mm Steel frame
one side. 28mm
Furring channel the other
20mm one side KOROK® 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
KIM02 57 -/60/60 122mm 28mm Furring
channel one side
N/A KOROK® 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB Noiseline® each side
KIM03 58 -/60/60 167mm 28mm Furring
channel each side
N/A  KOROK® 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB Noiseline® each side
KIM04 59 -/60/60 161mm 64mm Steel frame
one side
20mm one side KOROK® 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
KIM05 68 -/60/60 240mm 64mm Steel frame
each side
86mm overall. Framing not to touch KOROK® panel KOROK® 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
KIM06 59 -/120/120 188mm 64mm Steel frame
one side
20mm one side KOROK® 78mm panels (400 Kg/m3 density) + 1 layer 13mm GIB Noiseline® one side + 1 layer 13mm GIB® Standard other side
KIM07 56 -/120/120 188mm 64mm Steel frame
one side
20mm one side KOROK® 78mm panels (400 Kg/m3 density) + 1 layer 13mm GIB® Standard each side

Nominal measurement

 