Auckland Film Studio and Sound Stage

Auckland Film Studio and Sound Stage

CASE STUDY

Auckland Film Studio and Sound Stage

KOROK is proud to have supplied the critical fire and acoustic wall systems for the Auckland Film Studio and Sound Stage project. Designed by Ignite Architects and built by Haydn & Rollett Construction, this facility sets a new standard in the New Zealand cinema industry.

KOROK’s Contribution

Our 78mm KOROK panels Gen 2 were chosen for their superior fire and sound-rated properties, achieving a Noise Criterion rating below NC-20. This was crucial in ensuring optimal recording conditions, despite the studios’ proximity to urban noise sources like Auckland’s western rail line.

Sustainable Design and Construction

The project has been awarded a 4 Green Star As-Built rating, recognizing its sustainable design and construction practices.

KOROK is honoured to contribute to a project that not only pushes the boundaries of film studio design but also promotes sustainability and economic growth in Auckland. We look forward to seeing the long-term benefits this project will bring to the local community and the entertainment industry.

Auckland Film Studio and Sound Stage
Auckland Film Studio and Sound Stage

KOROK Systems used in this project

Cinemas

KOROK Cinemas

KOROK® is the number one choice for sound-proofing in New Zealand cinemas.

Related Projects

Read more
Fire and Acoustic Rated Protection for Cinemas

Bayfair Cinemas

CASE STUDY

Bayfair Cinemas

The Bayfair Cinemas project is part of a $115 million development that marked the introduction of United Cinemas to New Zealand. United Cinemas, a prestigious Australian-owned chain, has been a leader in the industry since 1987. Known for its luxury cinema experience, United Cinemas operates 46 theatres across Australia, and Bayfair Cinemas in Mount Maunganui is its first venture in New Zealand. The complex includes seven state-of-the-art screens, featuring the region’s largest screen with Dolby Atmos Digital Sound, creating an unmatched cinematic experience.

Bayfair Cinemas

KOROK® Acoustic Solutions for Cinemas

KOROK® systems were selected for this project to provide industry-leading acoustic performance. Our 78mm KOROK® panels were installed throughout the cinema complex, ensuring superior soundproofing between screens and public areas. This acoustic control is essential for a seamless and immersive movie experience, eliminating external noise and maintaining sound quality within each theatre.

KOROK® is recognized as the number one choice for soundproofing in New Zealand cinemas, thanks to our ability to deliver fire-resistant, durable, and cost-efficient wall systems that also meet the high acoustic demands of modern theatres.

Why Choose KOROK® for Cinemas?

  • Superior Acoustic Control: Our panels are engineered to significantly reduce noise transmission between spaces.
  • Fire-Resistant Performance: KOROK® systems comply with stringent fire safety regulations, ideal for public spaces like cinemas.
  • Cost-Efficient Installation: KOROK® panels can be installed quickly, reducing both time and labor costs.

The Bayfair Cinemas project is a showcase of KOROK®’s commitment to delivering top-tier acoustic and fire-rated solutions for high-performance environments like cinemas. 

Fire and Acoustic Rated Protection for Cinemas

KOROK Systems used in this project

Cinemas

KOROK Cinemas

KOROK® is the number one choice for sound-proofing in New Zealand cinemas.

Related Projects

Read more
Hoyts Cinema Complex

Hoyts Cinema Complex

CASE STUDY

Hoyts Cinema Complex, – KOROK® Wall Systems in Action

The Ormiston Hoyts Cinema Complex is part of a large shopping mall development in South Auckland’s Flat Bush. With eight theatres, the project required effective soundproofing to enhance the cinema experience.

KOROK® Panels for Acoustic Performance

The theatre walls feature a double layer of 78mm KOROK® panels with a gap filled with acoustic batts, designed to prevent sound from travelling between theatres. This setup ensures clear and uninterrupted sound for moviegoers.

Why KOROK® for Cinemas?

KOROK® wall systems are known for their acoustic properties, making them a common choice for cinemas in New Zealand. These panels help manage sound, offer fire protection, and are straightforward to install, meeting both safety and performance needs. For more information about how KOROK® can support your next project, contact us today.

Hoyts Cinema Complex
2019 Cinemas Ormiston (156)

KOROK Systems used in this project

Cinemas

KOROK Cinemas

KOROK® is the number one choice for sound-proofing in New Zealand cinemas.

Related Projects

Read more
KOROK® 78mm Galv Panel

KOROK® 78mm Galv Panel

KOROK® 78mm Galv Panel

High Performing and Lightweight

KOROK® 78mm galv panels are rollformed from zinc coated steel strips. The steel from which the shells are manufactured conforms to AS/NZS1397:2001.

Steel shells have a base metal thickness of 0.4mm B.M.T. with a Z275 zinc coating. These panels have an aerated concrete core and weigh nominally 10.2kg per lineal metre.

Read more
Lift Shafts, Risers, Ducts Fire and Acoustic Rated Protection

Lift Shafts, Risers, Ducts Fire and Acoustic Rated Protection

Lift Shafts, Risers, Ducts – Fire and Acoustic Rated Protection

KOROK® fire and acoustic rated wall systems offer superior solutions for lift shafts, risers, and ducts. With our innovative panel design, you can install from one side only, eliminating the need for internal scaffolding and significantly reducing construction time and costs.

Key Advantages:

  • Single-side installation: No scaffolding required inside the shaft, speeding up the construction process.
  • Pre-weather installation: KOROK® panels can be installed before the building is watertight, protecting against water ingress through open shafts and risers.
  • Fire and acoustic performance: Our systems provide high-level fire resistance and acoustic insulation, ensuring safety and comfort.

For more information or technical support on KOROK® fire and acoustic solutions for lift shafts, risers, and ducts, contact us today. We’re here to assist with any questions or specific project requirements.

Lift Shafts, Risers, Ducts Fire and Acoustic Rated Protection
Ian Trust 021 750 930 National Sales Manager/Director
Paul Carrigan 021 811 830 Specification Sales
Andrew Hawkins 027 498 3899 Specification Sales

Download Literature

KOROK Lift Shaft, Risers, Ducts Systems

Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more
Fire and Acoustic Rated Protection for Cinemas

Fire and Acoustic Rated Protection for Cinemas

Fire and Acoustic Rated Protection for Cinemas

KOROK® is the leading provider of fire and acoustic rated protection for cinemas across New Zealand. Our systems are specifically designed to deliver superior soundproofing and fire resistance, making them the ideal choice for cinema construction and renovation projects.

Why Choose KOROK® for Cinemas?

  • Superior Soundproofing: Our fire-rated wall systems ensure minimal sound transmission between auditoriums, enhancing the cinema experience.
  • High Fire Resistance: KOROK® systems provide reliable fire protection, meeting New Zealand’s building code requirements for safety.
  • Proven Performance: With years of successful installations, KOROK® has become the trusted name in cinema construction.
Cinemas

Download Literature

KOROK Cinema Systems

Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more
Intertenancy Apartment Systems Fire and Acoustic Rated Protection

Intertenancy Apartment Systems Fire and Acoustic Rated Protection

Fire and Acoustic Rated Protection for Intertenancy Apartment Systems

In multilevel buildings such as apartments and hotels, traditional framed wall systems often depend on wall linings to achieve fire resistance and effective acoustic control. However, KOROK® has designed an innovative solution: KIR KOROK® Intertenancy Residential Walls. These advanced wall systems eliminate the need for linings in the ceiling plenum while maintaining exceptional fire resistance and acoustic performance.

This breakthrough simplifies the design, detailing, and construction of intertenancy apartment walls, leading to quicker construction times, less material waste, and significant cost savings.

Key Benefits of KOROK® Intertenancy Apartment Walls:

  • Proven fire-rated protection and acoustic insulation for multilevel buildings.
  • Solid wall construction for enhanced security and long-term durability.
  • Faster installation process, reducing overall project timelines.
  • Eco-friendly solution with waste reduction..

Explore our CAD Library to access detailed DWG files for multilevel intertenancy systems. Download the full KOROK Intertenancy Multilevel Systems Literature to learn more about our fire and acoustic rated protection.

Download Literature

KOROK Intertenancy Multilevel Systems

Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more
System Selector

System Selector

device top

KOROK® SYSTEM SELECTOR

Choose the right system for your next project

device bottom

Find, Compare & Download the best KOROK System

  • Use filters to refine your search.
  • Use the ‘CTRL’ key for multiple selections.
Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more
Intertenancy Terraced Housing Systems

Intertenancy Terraced Housing Systems Fire and Acoustic Rated Protection

Intertenancy Terraced Housing Systems – Fire and Acoustic Rated Protection

In modern terraced housing and townhouses, traditional framed wall systems depend on internal linings to provide fire resistance. Any penetration through these linings can compromise the fire-rated barrier, increasing the risk of fire spread. The KOROK® Intertenancy System offers a superior solution, where the primary fire barrier is located between the structural frames, protecting the building on the side opposite to the fire.

How KOROK® Intertenancy Systems Work

The KOROK® Intertenancy System utilizes aluminium brackets to attach the KOROK® fire-rated panels to both frames. In the event of a fire, the brackets on the fire-exposed side melt, allowing the structure on the fire side to detach safely. This innovative design ensures that the KOROK® panels remain securely supported by the brackets connected to the non-fire side, providing continued fire protection and maintaining the integrity of the structure.

Acoustic and Fire-Rated Solutions for Terraced Housing

In addition to superior fire resistance, the KOROK® Intertenancy System offers excellent acoustic insulation, making it an ideal solution for townhouses and multi-residential developments. By minimizing noise transfer between units, the KOROK® system enhances privacy and comfort for occupants.

KOROK® Cantilever Design

The KOROK® Cantilever feature in the Intertenancy Terraced Housing Systems ensures that the panels remain stable during a fire, further enhancing the safety and reliability of the system. This design meets strict building code requirements and is fully tested to withstand fire scenarios. KOROK® Cantilevers

Download Literature

KOROK Intertenancy Terraced Housing Systems

Link to System SpecPanelsSTCSTC RatingFRRFire RatingOverall System ThicknessLiningFrameCavityFlashingDensityApplicationView CAD Files in LibraryMasterSpec Work Section
EX1




78mm3636-40 -/120/120120n/ano linings n/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX278mm4241-54 -/180/180180n/a1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternativesn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX378mm3636-40 -/120/120120n/aLongrun profiled steel cladding system as selectedn/an/a400 kg/m3External4259KE - Korok Exterior Wall Systems
EX478mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives.
Longrun profiled steel cladding system as selected.
n/an/a400 kg/m3External

4259KE - Korok Exterior Wall Systems
EX578mm4241-54 -/180/180180n/aThe internal side lined with 1 layer 19mm GIB Fyreline® or acceptable GIB® alternatives or 2 layers 10mm GIB Fyreline® or acceptable GIB® alternatives. Longrun profiled steel cladding system as selectedn/an/a400 kg/m3External
4259KE - Korok Exterior Wall Systems
FS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS278mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track.400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS378mm4036-40 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
FS478mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
KIM0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one side28mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard each side64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0851mm6160-64 -/60/6030-60181mm1 layer 13mm to GIB® Noiseline or equivalent each side64mm steel frame one side16mm Furring channel on 237 clips direct fix the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM0951mm6060-64 -/60/6030-60175mm1 layer 13mm GIB Noiseline® or equivalent each side28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1251mm6160-64 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side64mm steel frame one side16mm Furring channel directly fixed the other. Minimum 10mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIM1351mm6460-64 -/60/6030-60194mm1 layer 13mm GIB® Noiseline or equivalent one side +2 layers 13mm GIB® Noiseline or equivalent the other64mm steel frame one side16mm Furring channel on direct fix clips the other. Minimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0151mm5855-59 -/60/6030-60194mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one side, 28mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel
5171KI - Korok Inter-tenancy Wall Systems
KIR0251mm5755-59 -/60/6030-60122mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0351mm5955-59 -/60/6030-60167mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on resilient mounts each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0451mm5955-59 -/60/6030-60161mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0551mm6865-and above -/60/6030-60240mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame each sideMinimum 86mm between the framing. Framing not to touch KOROK® panel600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0678mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0778mm5955-59 -/120/120120188mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
64mm steel frame one sideMinimum 20mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0851mm6160-64 -/60/6030-60181mm1 layer 13mm GIB® Noiseline or equivalent each side
64mm steel frame one side, 16mm Furring channel on direct fix clips the otherMinimum 20mm600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR0951mm6060-64 -/60/6030-60177mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BetaFix clips each siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1451mm5555-59 -/60/6030-60109mm1 layer 13mm GIB® Noiseline plasterboard or equivalent one side
28mm Furring channel on resilient mounts one siden/a600 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1578mm5655-59 -/120/120120141mm1 layer 13mm GIB Noiseline® or equivalent one side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1678mm5755-59 -/120/120120154mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips one siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1778mm6160-64 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1878mm5855-59 -/120/120120204mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent other side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR1978mm5555-59 -/120/120120204mm1 layer 13mm GIB® Standard plasterboard or equivalent each side
28mm Furring channel on BETAGRIP® Clips each siden/a400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2078mm6060-64 -/120/120120233mm1 layer 13mm GIB Noiseline® or equivalent one side + 1 layer 13mm GIB® Standard plasterboard or equivalent the other side
64mm steel frame one side, 28mm Furring channel on BETAGRIP® Clips the other sideMinimum 15mm400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIR2178mm6965-and above -/120/120120262mm1 layer 13mm GIB Noiseline® or equivalent each side
64mm steel frame each sideMinimum 108mm between the framing. Framing not to touch KOROK® panel400 kg/m3Apartment / multilevel5171KI - Korok Inter-tenancy Wall Systems
KIT01A51mm6460-6460/60/3030-60288mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0151mm6360-6460/60/6030-60288mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT01 Modified51mm6360-6460/60/6030-60282mm1 layer 10mm GIB® Standard plasterboard or equivalent each side
Acoustic insulation must be either Autex GreenStuf SW90 or Pink Batts R 2.2 each side.
KOROK® metal fire flashing is installed to the top C-track.
KOROK® metal KIT flashing is installed to horizontal joints.
90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0251mm6665-and above60/60/6030-60288mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0351mm6765-and above60/60/6030-60288mm1 layer 10mm GIB Noiseline® each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0451mm6965-and above60/60/6030-60294mm1 layer 13mm GIB Noiseline® each side90mm steel or timber frame each side86mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0551mm6665-and above60/60/6030-60294mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side80mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.600 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT06A78mm6360-64120/120/6030-60315mm1 layer 10mm GIB® Standard each side 90mm90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy
5171KI - Korok Inter-tenancy Wall Systems
KIT0678mm6360-64120/120/120120315mm1 layer 10mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0778mm6665-and above120/120/120120315mm1 layer 10mm GIB® Standard one side, 1 layer 10mm GIB Noiseline® other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0878mm6765-and above120/120/120120315mm1 layer 10mm GIB Noiseline® one side, 1 layer 10mm GIB Aqualine (wet) or 10mm GIB Noiseline® (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT0978mm6965-and above120/120/6030-60321mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB Aqualine (wet) or 13mm Noiseline (dry) other side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KIT1078mm6665-and above120/120/120120321mm1 layer 13mm GIB® Standard each side90mm steel or timber frame each side113mm overall. Framing not to touch KOROK® panel or fire flashingKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Terraced housing intertenancy5171KI - Korok Inter-tenancy Wall Systems
KLSD6
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD7
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD8
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® direct-fixed one side OR 2 layers 10mm GIB Fyreline® direct-fix one side n/an/a400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KLSD9
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Riser / shafts / ducts

5216KC - Korok® Commercial Interior Wall Systems
KWR1
78mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR2
78mm3636-40 -/120/12012078mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track. KOROK® metal KIT flashing is installed to horizontal joints.400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3A
78mm4241-54 -/180/18018098mm2 layers 10mm GIB Fyreline® direct-fixed one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3B
78mm4241-54 -/180/18018097mm1 layer 19mm GIB Fyreline® one side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR3
78mm4241-54 -/180/180180104mm1 layer 13mm GIB Fyreline® each side n/an/a400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR4
78mm x25555-59 -/240/240240206mmno linings n/aMinimum 50mm between KOROK® panels400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR5
78mm5855-59 -/120/120120175mm1 layer 13mm GIB Noiseline® one side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
KWR6
78mm5955-59 -/120/120120188mm1 layer 13mm GIB Noiseline® one side, 1 layer 13mm GIB® Standard other side64mm steel frame one sideMinimum 20mm400 kg/m3Warehouse / retail / factory5216KC - Korok® Commercial Interior Wall Systems
NCS178mm3636-40 -/120/6030-6078mmno linings n/an/a400 kg/m3Noise control<img decoding="async" src="https://www.korok.com/wp-content/uploads/2024/06/FS1-vertical-150x150.png" alt="" width="150" height="150" 5216KC - Korok® Commercial Interior Wall Systems
NCS278mm5855-59 -/120/120120175mm1 layer of 13mm GIB Noiseline® + R1.8 insulation64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS378mm5955-59 -/120/120120188mm1 layer of 13mm GIB Noiseline® on one side with R1.8 insulation, 1 layer of 13mm GIB® Standard on the other side64mm steel frame one sideMinimum 20mm400 kg/m3Noise control
5216KC - Korok® Commercial Interior Wall Systems
NCS478mm x27665-and above -/120/120120600mm1 layer 90mm x 42kg/m3 insulation attached to one internal facen/a444mm between KOROK® panels600 kg/m3Cinema

5216KC - Korok® Commercial Interior Wall Systems
K5151mm3636-40 -/60/6030-6051mmno linings n/an/aKOROK® metal fire flashing is installed to the top C-track
OR
13 mm GIB Fyreline® or acceptable GIB® alternatives x 120 mm strip with
sealant is fixed at 250 mm centres top and bottom, using 6g x 32 mm
drywall screws.
600 kg/m3Fire system5216KC - Korok® Commercial Interior Wall Systems
See Scissor Stair information hereScissor stairs
See Passive Fire / Penetrations information here Passive fire / penetrations
See Connections to Steel information here Connections to steel
Read more